<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>output | ELGi</title>
	<atom:link href="https://blog.elgi.com/tag/output/feed/" rel="self" type="application/rss+xml" />
	<link>https://blog.elgi.com</link>
	<description>A digital destination to share knowledge and industry insights on compressed air</description>
	<lastBuildDate>Mon, 28 Nov 2022 14:16:44 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://blog.elgi.com/wp-content/uploads/2020/09/ELGi-favicon.jpg</url>
	<title>output | ELGi</title>
	<link>https://blog.elgi.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Does air compressor CFM refer to intake or output?</title>
		<link>https://blog.elgi.com/knowledge-center/does-air-compressor-cfm-refer-to-intake-or-output/</link>
		
		<dc:creator><![CDATA[EBadmin]]></dc:creator>
		<pubDate>Thu, 17 Nov 2022 12:31:45 +0000</pubDate>
				<category><![CDATA[Knowledge Center]]></category>
		<category><![CDATA[ambient pressure]]></category>
		<category><![CDATA[CFM]]></category>
		<category><![CDATA[discharge]]></category>
		<category><![CDATA[ideal gas law]]></category>
		<category><![CDATA[input]]></category>
		<category><![CDATA[ISO1217]]></category>
		<category><![CDATA[output]]></category>
		<category><![CDATA[suction]]></category>
		<guid isPermaLink="false">https://blog.elgi.com/?p=6390</guid>

					<description><![CDATA[<p>CFM vs FAD:  Ever thought about how we conveniently call every photocopier &#8220;Xerox&#8221; and every portable music player &#8220;Walkman&#8221;? This is a phenomenon where a non-generic term is more popular than a generic term.  We do have something similar in the compressor industry. We often hear the word CFM mentioned by customers, designers, marketers, and &#8230; <a href="https://blog.elgi.com/knowledge-center/does-air-compressor-cfm-refer-to-intake-or-output/" class="more-link">Continue reading <span class="screen-reader-text">Does air compressor CFM refer to intake or output?</span></a></p>
The post <a href="https://blog.elgi.com/knowledge-center/does-air-compressor-cfm-refer-to-intake-or-output/">Does air compressor CFM refer to intake or output?</a> first appeared on <a href="https://blog.elgi.com">ELGi</a>.]]></description>
										<content:encoded><![CDATA[<p><b><span data-contrast="auto">CFM vs FAD:</span></b><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p><span data-contrast="auto">Ever thought about how we conveniently call every photocopier &#8220;Xerox&#8221; and every portable music player &#8220;Walkman&#8221;? This is a phenomenon where a non-generic term is more popular than a generic term.</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p><span data-contrast="auto">We do have something similar in the compressor industry. We often hear the word CFM mentioned by customers, designers, marketers, and other stakeholders in a sales pitch, product presentation, or design review. CFM is expanded as Cubic Feet per Minute (CFM). The CFM they talk about is Free Air Delivery (FAD) and not the unit of measurement.</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p><span data-contrast="auto">FAD is the actual volume of compressed air delivered by the compressor at </span><b><span data-contrast="auto">Delivery </span></b><span data-contrast="auto">while considering the </span><b><span data-contrast="auto">Suction </span></b><span data-contrast="auto">conditions of the free air taken in. It is the volume of free air drawn at atmospheric conditions by the compressor, compressed and delivered at a specific pressure. CFM being the imperial unit of Measure of FAD is quite often understood as a FAD. Let us now try to understand the measurement of FAD.</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p><b><span data-contrast="auto">CFM &#8211; The imperial unit:</span></b><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p><span data-contrast="auto">CFM is the imperial unit of measurement of the compressor Free Air Delivery (FAD). There are also other units such as lpm in the SI system, m3/min (in some markets), etc.</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p>&nbsp;</p>
<p><b><span data-contrast="auto">FAD Measurement at Actual, Normal, and Standard conditions:</span></b><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p><span data-contrast="auto">FAD measurement is commonly misunderstood as plugging a flow meter in the discharge side of the compressor, whereas the sensor which is fitted is calibrated to show the actual FAD of the compressor referring to the inlet conditions. An interesting thing about FAD measurement is that it is subject to change, considering ambient conditions. When a compressor is validated at the ELGi factory (Coimbatore, India), the validation expert measures the FAD at Coimbatore ambient conditions (38 °C, 1 bar). The measured FAD is known as Actual FAD (acfm). But, for a customer using the compressor in an end application point situated at Charlotte, the acfm value makes better sense when converted to a set of reference conditions. There are two commonly used reference conditions, namely standard conditions. When acfm is converted to standard reference conditions, the FAD is measured as Standard Cubic Feet per Minute (scfm) or Sm3/min. Similarly, when acfm is converted to normal reference conditions, the FAD is measured as normal Cubic Feet per Minute (ncfm) or Nm3/min.</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p><b><span data-contrast="auto">Standard reference conditions:</span></b><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">Standard reference temperature = 20°C (68°F)</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">Standard reference pressure = 14.7psi (1.013bar)</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">Standard reference relative humidity = 36%</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p>&nbsp;</p>
<p style="text-align: left;"><strong>Normal reference conditions:</strong><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">Normal reference temperature = 0°C (32°F)</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">Normal reference pressure = 14.7psi (1.013bar)</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">Normal reference Relative Humidity = 0%.</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p><b><span data-contrast="auto">Significance of Normal/Standard vs Actual FAD when sizing a centrifugal compressor:</span></b><span data-ccp-props="{}"> </span></p>
<p><span data-contrast="auto">A centrifugal compressor is a non-positive displacement (or) dynamic compressor. They are different from a positive displacement compressor which works at a </span><b><span data-contrast="auto">constant flow</span></b><span data-contrast="auto">. Dynamic compressor work at </span><b><span data-contrast="auto">constant pressure</span></b><span data-contrast="auto"> and the performance is affected by ambient conditions such as changes in inlet temperature, Mean Sea Level (MSL), Relative humidity, etc. Hence when conditions change, the FAD changes, and hence the ability to do work on a pneumatic tool or actuator increases or decreases with those changes. So, the conversion from acfm (m3/min) to scfm (Sm3/min) is critical when sizing a centrifugal compressor. </span><span data-ccp-props="{&quot;335559731&quot;:720}"> </span></p>
<p>&nbsp;</p>
<p><b><span data-contrast="auto">The debate between intake or output:</span></b><span data-ccp-props="{}"> </span></p>
<ol>
<li data-leveltext="%1)" data-font="Verdana" data-listid="3" data-list-defn-props="{&quot;335552541&quot;:0,&quot;335559684&quot;:-1,&quot;335559685&quot;:360,&quot;335559991&quot;:360,&quot;469769242&quot;:[65533,3],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;%1)&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}" aria-setsize="-1" data-aria-posinset="1" data-aria-level="1"><b><span data-contrast="auto">Empirical formula method:</span></b><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></li>
</ol>
<p><b><span data-contrast="auto">Ideal gas law: </span></b><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p><span data-contrast="auto">The ideal gas law is represented by the following formula,</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">PV=nRT</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">where P &#8211; pressure</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">V – volume</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">T – Temperature</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> </span></p>
<p style="text-align: center;"><span data-contrast="auto">n, R &#8211; constants</span><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}">  </span></p>
<p>&nbsp;</p>
<p style="text-align: center;"><span data-contrast="auto">The formula for FAD is merely a variation of the Ideal Gas law. The FAD formula contains three parameters such as pressure, temperature, and volume of the air at </span><b><span data-contrast="auto">suction</span></b><span data-contrast="auto"> and </span><b><span data-contrast="auto">discharge</span></b><span data-contrast="auto">. The formula is represented as follows,</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p><span data-ccp-props="{&quot;335551550&quot;:2,&quot;335551620&quot;:2}"> <img decoding="async" class="size-full wp-image-6391 alignright" src="https://blog.elgi.com/wp-content/uploads/2022/11/CFM-formula.png" alt="" width="112" height="46" /></span></p>
<p><span data-contrast="auto">Volume and volumetric flow rate are proportional, hence can be interchanged in the equation. The usage of both input and output parameters establishes the fact that FAD measurement is not based on the point of measurement but rather a combination of both. </span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p>&nbsp;</p>
<p><strong><i>Illustration</i></strong><span data-contrast="auto"><strong>:</strong> A lubricated screw compressor is compressing ambient air at 140cfm, 1bar to compressed air at 20 cfm, 7bar. The actual discharge end volumetric flow rate is 20 cfm, provided we assume the inter-lobe losses to be net zero, which is an </span><b><span data-contrast="auto">ideal</span></b> <b><span data-contrast="auto">condition</span></b><span data-contrast="auto"> assumption. This is validated by a technician using the nozzle method of flow measurement. Even though the C-D nozzle is fixed in the discharge end, the FAD calculated is referred to intake conditions, which means the header pipe from the discharge end contains compressed air at 7 bar and when the end user taps the pneumatic line, the air flows through the application which is at atmospheric conditions, thereby providing the customer the rated FAD.</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<ol>
<li data-leveltext="%1)" data-font="Verdana" data-listid="3" data-list-defn-props="{&quot;335552541&quot;:0,&quot;335559684&quot;:-1,&quot;335559685&quot;:360,&quot;335559991&quot;:360,&quot;469769242&quot;:[65533,3],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;%1)&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}" aria-setsize="-1" data-aria-posinset="2" data-aria-level="1"><b><span data-contrast="auto">The ISO methodology:</span></b><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></li>
</ol>
<p><span data-contrast="auto">The International Organization for Standards (ISO) describes the acceptance test for displacement compressors under ISO 1217.</span> <span data-contrast="auto">Clause 3.4.1 of ISO 1217 states:</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p><span data-contrast="auto">“</span><span data-contrast="none">Actual volume flow rate of a compressor is the actual volume flow rate of gas, compressed and delivered at the standard discharge point, referred to conditions of total temperature, total pressure and composition prevailing at the standard inlet point.</span><span data-contrast="auto">”</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p><span data-contrast="auto">Section 6.2 has laid out “thirteen parameters” whose fluctuations can be moving the needle haphazardly while measuring FAD. These parameters are measured using sensors at the </span><b><span data-contrast="auto">Suction</span></b> <span data-contrast="auto">and </span><b><span data-contrast="auto">Discharge</span></b> <span data-contrast="auto">side as well as depending on the gas properties and the prime mover. Based on this, one can conclude that FAD measurement is not dependent on the point of measurement but rather a scientific application of inlet/outlet parameters to arrive at a meaningful flow parameter. The ISO method is seconding the conclusion drawn from the empirical formula method.</span><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720}"> </span></p>
<p><img fetchpriority="high" decoding="async" class="aligncenter size-full wp-image-6392" src="https://blog.elgi.com/wp-content/uploads/2022/11/Flow-diagram-for-Blog-V5-01-1-scaled.jpg" alt="" width="2560" height="1220" srcset="https://blog.elgi.com/wp-content/uploads/2022/11/Flow-diagram-for-Blog-V5-01-1-scaled.jpg 2560w, https://blog.elgi.com/wp-content/uploads/2022/11/Flow-diagram-for-Blog-V5-01-1-300x143.jpg 300w, https://blog.elgi.com/wp-content/uploads/2022/11/Flow-diagram-for-Blog-V5-01-1-1024x488.jpg 1024w, https://blog.elgi.com/wp-content/uploads/2022/11/Flow-diagram-for-Blog-V5-01-1-768x366.jpg 768w, https://blog.elgi.com/wp-content/uploads/2022/11/Flow-diagram-for-Blog-V5-01-1-1536x732.jpg 1536w, https://blog.elgi.com/wp-content/uploads/2022/11/Flow-diagram-for-Blog-V5-01-1-2048x976.jpg 2048w" sizes="(max-width: 2560px) 100vw, 2560px" /></p>
<p><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p><b><span data-contrast="auto">Conclusion:</span></b><span data-ccp-props="{&quot;335551550&quot;:6,&quot;335551620&quot;:6}"> </span></p>
<p><span data-contrast="auto">Whenever someone raises the question, &#8220;</span><b><span data-contrast="auto">Does air compressor CFM refer to intake or output?</span></b><span data-contrast="auto">&#8220;, we can confidently answer that FAD is a flow parameter of an air compressor that can be derived using both </span><b><span data-contrast="auto">Suction </span></b><span data-contrast="auto">and </span><b><span data-contrast="auto">Discharge </span></b><span data-contrast="auto">parameters, and it is not a parameter dependent on the point of measurement. FAD is the quantity of compressed air measured at discharge, converted back to inlet conditions of the compressor.</span><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>
<p><a href="https://www.elgi.com/id/request-an-appointment/"><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> <img decoding="async" class="aligncenter size-full wp-image-6393" src="https://blog.elgi.com/wp-content/uploads/2022/11/CFM-Blog-Images-V2_FB_Footer-banner.jpg" alt="" width="1800" height="381" srcset="https://blog.elgi.com/wp-content/uploads/2022/11/CFM-Blog-Images-V2_FB_Footer-banner.jpg 1800w, https://blog.elgi.com/wp-content/uploads/2022/11/CFM-Blog-Images-V2_FB_Footer-banner-300x64.jpg 300w, https://blog.elgi.com/wp-content/uploads/2022/11/CFM-Blog-Images-V2_FB_Footer-banner-1024x217.jpg 1024w, https://blog.elgi.com/wp-content/uploads/2022/11/CFM-Blog-Images-V2_FB_Footer-banner-768x163.jpg 768w, https://blog.elgi.com/wp-content/uploads/2022/11/CFM-Blog-Images-V2_FB_Footer-banner-1536x325.jpg 1536w" sizes="(max-width: 1800px) 100vw, 1800px" /></span></a></p>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-6394" src="https://blog.elgi.com/wp-content/uploads/2022/11/Author-Banner_Meshach-Samuel-Raj-R-V1_800x200-scaled.jpg" alt="" width="2560" height="640" srcset="https://blog.elgi.com/wp-content/uploads/2022/11/Author-Banner_Meshach-Samuel-Raj-R-V1_800x200-scaled.jpg 2560w, https://blog.elgi.com/wp-content/uploads/2022/11/Author-Banner_Meshach-Samuel-Raj-R-V1_800x200-300x75.jpg 300w, https://blog.elgi.com/wp-content/uploads/2022/11/Author-Banner_Meshach-Samuel-Raj-R-V1_800x200-1024x256.jpg 1024w, https://blog.elgi.com/wp-content/uploads/2022/11/Author-Banner_Meshach-Samuel-Raj-R-V1_800x200-768x192.jpg 768w, https://blog.elgi.com/wp-content/uploads/2022/11/Author-Banner_Meshach-Samuel-Raj-R-V1_800x200-1536x384.jpg 1536w, https://blog.elgi.com/wp-content/uploads/2022/11/Author-Banner_Meshach-Samuel-Raj-R-V1_800x200-2048x512.jpg 2048w" sizes="auto, (max-width: 2560px) 100vw, 2560px" /></p>
<p><span data-ccp-props="{&quot;201341983&quot;:0,&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559731&quot;:720,&quot;335559739&quot;:0,&quot;335559740&quot;:240}"> </span></p>The post <a href="https://blog.elgi.com/knowledge-center/does-air-compressor-cfm-refer-to-intake-or-output/">Does air compressor CFM refer to intake or output?</a> first appeared on <a href="https://blog.elgi.com">ELGi</a>.]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
